Home Page / 2007 (unverified) Corinsa CCR21.35 Pneumatic Compactor
 
Previous Next
Bidding Ends
1 day, 2 hours (Subject to early close)
Starting Bid
€18,000
0 bids    Reserve not metHow Bidding Works
Bid Increment
€500

  
You will confirm this bid on the next page. How Bidding Works How Bidding Works
ITEM DETAILS
5,060 Hours
Open Operator Station, 15.00R24 Tires, Variable Tire Pressure System, Water System, Deutz Engine,

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark (on or near data plate) No plate
CE Certificate Available No
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Exterior Lights Functional Some not operational Click here to open photos and videos of this item.  
(5)


Safety
Description Rating Details  
Travel Alarm Missing
Horn Operational
Seat belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station - Compactor
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/armrests Damaged frame Click here to open photos and videos of this item.  
Function Controls Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Oil Pressure Warning light inoperable Click here to open photos and videos of this item.  
Engine Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (Start) 5,060 Hours Click here to open photos and videos of this item.  
Hour Meter (Ending) 5,060 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check (cs) The main components are in place and operational.
(14)


Engine
Description Rating Details  
Emission Control Label None found
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Oil Leaks Oil Filler pipe Click here to open photos and videos of this item.  
Fuel Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(12)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Chains/Sprockets Click here to open photos and videos of this item.  
Limited Function Check - Compaction The drivetrain was operational without a load.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics)
Steering Cylinders Click here to open photos and videos of this item.  
Limited Function Check Oil leak in the seat rotation system; Suspension cylinders doesn't lift
(5)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Drum Scraper Click here to open photos and videos of this item.  
Water System Unable to test Click here to open photos and videos of this item.  
Frame Condition
Ballast Tank Click here to open photos and videos of this item.  
Master Cylinder/Brake Control Click here to open photos and videos of this item.  
Brake Lines/Hoses
Park Brake Click here to open photos and videos of this item.  
Tyre Condition Click here to open photos and videos of this item.  
Wheel Condition Click here to open photos and videos of this item.  
Limited Function Check (roller) The main chassis components were operational.
(11)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.