Home Page / 2007 Case CX210B NLC Track Excavator
 
Previous Next
Auction Closed on
23/09/16
Opened At
€28,000
NOT SOLD
ITEM DETAILS
5,203 Hours
Enclosed Cab, Air Conditioner, Heater, 2.45m Stick, 580mm Track Shoes, Boom Check Valve, Stick Check Valve, CE Plate.

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark (on or near data plate) Yes
CE Certificate Available Copy Only Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Bent panels. Hole in panel. Click here to open photos and videos of this item.  
Exterior Lights Functional Operational; To on top cab missing Click here to open photos and videos of this item.  
(10)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Operational
Seat belts Operational
Safety lock out/stop Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Mirrors Cracked Click here to open photos and videos of this item.  
Seats/armrests Small hole in cover Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Engine Warning Lights Operational Click here to open photos and videos of this item.  
Hour Meter (Start) 5,203 Hours Click here to open photos and videos of this item.  
Hour Meter (Ending) 5,203 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner The ambient temperature is too cold to check.
Heater Operational
Limited Function Check (cs) The main components operated except as noted. Click here to open photos and videos of this item.  
(13)


Engine
Description Rating Details  
Emission Control Label Both EPA and EC certification Click here to open photos and videos of this item.  
Engine Serial Number 4HK1-420802 Click here to open photos and videos of this item.  
A/C Compressor Operational Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Click here to open photos and videos of this item.  
(9)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(4)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Swing Motor Click here to open photos and videos of this item.  
Boom Lift Cylinder(s) Click here to open photos and videos of this item.  
Stick Cylinder Click here to open photos and videos of this item.  
Bucket Cylinder Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(9)


Chassis
Description Rating Details  
Boom Condition Click here to open photos and videos of this item.  
Stick Condition Click here to open photos and videos of this item.  
Boom Base Pin and Bushings Click here to open photos and videos of this item.  
Pin and Bushings Boom to Stick Click here to open photos and videos of this item.  
Pins and Bushings Stick to Coupler Click here to open photos and videos of this item.  
Turn-table Bearing Click here to open photos and videos of this item.  
Bottom Covers Missing plate Click here to open photos and videos of this item.  
Limited Function Check (Backhoe) The main components were operational in a limited check.
(7)


Undercarriage - Crawler Excavator
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Roller Frames Click here to open photos and videos of this item.  
Track Tensioners No visible damage
Track Pads Click here to open photos and videos of this item.  
Grouser Height Left Side: 25 mm; Right Side: 25 mm Click here to open photos and videos of this item.  
Track link wear Click here to open photos and videos of this item.  
Track Bushings Worn Click here to open photos and videos of this item.  
Carrier rollers wear Click here to open photos and videos of this item.  
Track rollers wear Click here to open photos and videos of this item.  
Idlers Click here to open photos and videos of this item.  
Sprockets Worn & chipped Click here to open photos and videos of this item.  
(15)


Specialty
Description Rating Details  
Quick Connect Click here to open photos and videos of this item.  
(3)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.