Home Page / 2007 Himoinsa HYW-35 T5 Generator
 
Previous Next
Sold on
30/11/16
Winning Bid
€2,300
# of Bids
4
SOLD!
ITEM DETAILS
10,241 Hours
32 kVA, 28 kW, 400 Volts 3 Phase, 230 Volts Single Phase, 230V Receptacles (Blue), 400V Receptacles (Red), Fuel Tank, Skid Mounted, Insulated Enclosure, Container Enclosure, CE Mark

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Generator/Welder Serial Number 7102855
CE Mark (on or near data plate) Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(9)


Control Station
Description Rating Details  
Gauges Gauges Hz don't work Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Engine Warning Lights Operational Click here to open photos and videos of this item.  
Hour Meter (Start) 10,240 Hours Click here to open photos and videos of this item.  
Hour Meter (Ending) 10,241 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check (cs) The main components are in place and operational. Click here to open photos and videos of this item.  
(10)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Injector pump Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Missing fan guard. Click here to open photos and videos of this item.  
Oil Leaks None seen Click here to open photos and videos of this item.  
Fuel Leaks None seen Click here to open photos and videos of this item.  
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(15)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Disconnect Switch Functional Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Operational Click here to open photos and videos of this item.  
Receptacles Click here to open photos and videos of this item.  
Limited Function Check (Power Unit) The generator was not checked for electrical output.
(10)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(2)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.