ITEM DETAILS
4,517 Hours
152 kVA, 400 Volts 3 Phase, 220 Volts Single Phase, 230V Receptacles (Blue), 400V Receptacles (Red), Perkins Engine, Bottom Mounted Fuel Tank, Insulated Enclosure, CE Plate

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Generator/Welder Serial Number 84145070005 Click here to open photos and videos of this item.  
CE Mark (on or near data plate) Yes Click here to open photos and videos of this item.  
CE Certificate Available Copy Only Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(7)


Control Station
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Engine Warning Lights Operational Click here to open photos and videos of this item.  
Hour Meter (Start) 4517,2 Hours Click here to open photos and videos of this item.  
Hour Meter (Ending) 4,517 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check (cs) The main components are in place and operational. Click here to open photos and videos of this item.  
(5)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Control Label None found Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Injector pump Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Click here to open photos and videos of this item.  
(14)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model No tag found Click here to open photos and videos of this item.  
Disconnect Switch Functional Click here to open photos and videos of this item.  
Cables and Connections
Emergency Shut Off Switch Operational Click here to open photos and videos of this item.  
Receptacles Click here to open photos and videos of this item.  
Limited Function Check (Power Unit) Functioned when checked without a load.
(10)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.