Home Page / 2008 Atlas Copco QAC1000 Generator
 
Previous Next
Sold on
30/11/16
Winning Bid
€23,000
# of Bids
78
SOLD!
ITEM DETAILS
16,558 Hours
1000kVA, 400 Volts 3 Phase, Deutz TCD2016 V16 G2 Engine, Bottom Mounted Fuel Tank, Insulated Enclosure, Container Enclosure, CE Plate **TRAILER NOT INCLUDED**

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Generator/Welder Serial Number AIP693436 Click here to open photos and videos of this item.  
CE Mark (on or near data plate) Yes
CE Certificate Available No
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(4)


Control Station
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Oil Pressure No oil pressure indicator
Engine Warning Lights Operational
Hour Meter (Start) 16558 Hours Click here to open photos and videos of this item.  
Hour Meter (Ending) 16,558 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check (cs) The main components are in place and operational.
(4)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) Minor
Starter Operational
Injector pump Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Control relay for roof doors missing Click here to open photos and videos of this item.  
Oil Leaks None found
Fuel Leaks None seen
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran.
(12)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model Stamford; AO7K903366 generator; Serial#: 0236759/001 Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Not operationally checked Click here to open photos and videos of this item.  
Receptacles Click here to open photos and videos of this item.  
Limited Function Check (Power Unit) The generator was not checked for electrical output.
(11)
 

Oil Sample Analysis
  engine
Tin <1 PPM
Lead <1 PPM
Chromium <1 PPM
Aluminum 2 PPM
Copper 1 PPM
Silicon 14 PPM
Iron 10 PPM
Nickel <1 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.