ITEM DETAILS
9,400 Hours
4 Lamps, Lombardini LDW1003GE Engine, Power Receptacles, Trailer Mounted, Ball Hitch, CE Plate ***All items located in Poland that will be exported out of the EU require an IE599 document retrieved from the Polish customs authority and submitted to IronPlanet Ltd. VAT will be applied to all transactions. On receipt of the IE599 documentation and corresponding BOLs/CMRs, VAT will be refunded to the buyer immediately***

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Light Tower Serial Number 5555444 Click here to open photos and videos of this item.  
CE Certificate Available No
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
(7)


Control Station
Description Rating Details  
Hour Meter (Start) 9,399.4 Hours Click here to open photos and videos of this item.  
Hour Meter (Ending) 9,400.2 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Function Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Engine Warning Lights Operational Click here to open photos and videos of this item.  
Limited Function Check (cs) The main components are in place and operational. Click here to open photos and videos of this item.  
(7)


Engine - Light Tower
Description Rating Details  
Fuel Type Diesel
Emission Control Label None found Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Injector pump Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(9)


Chassis - Light Tower / Message Board
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Left Tire Click here to open photos and videos of this item.  
Right Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition 5 cm Ball hitch
Power Receptacle Functional Yes Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Outrigger Condition Click here to open photos and videos of this item.  
(14)


Light Tower / Message Board
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Functionally checked to power lights Click here to open photos and videos of this item.  
Light Tower Mast Click here to open photos and videos of this item.  
Light Tower Lamps Operational Yes; 3 of the 4 Click here to open photos and videos of this item.  
Light Tower / Message Board #1 Click here to open photos and videos of this item.  
(14)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.