ITEM DETAILS
2,564 Hours
Enclosed Cab,Heater, A/C, Mercedes Benz Engine, 3 Boom System, AutoLube system, Dual wheel on front.

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark (on or near data plate) No
CE Certificate Available No
Paint Scratches,chips,faded,rust Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Dents,cracks on fenders Click here to open photos and videos of this item.  
Steps/Ladders No visible damage Click here to open photos and videos of this item.  
Hand Rails No visible damage Click here to open photos and videos of this item.  
(17)


Control Station
Description Rating Details  
Cab Glass No visible damage
Seats/armrests Minor torn cover
Seat belts Operational
Horn Operational
Control Lock Lever
Hydraulic Controls
Steering Controls
Powertrain controls
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Functional No
Engine Warning Lights Operational; Air filter entrance and engine temperature light stays on
Travel Alarm Operational
Gauges Operational
Hour Meter/Odometer (Start) 2,563 Hours
Hour Meter/Odometer 2,564 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Air Conditioner Operational; Cool but not cold; Missing caps
Heater Operational
Limited Function Check (cs) The main components are in place and operational.
(25)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) No noticeable vapor or pressure; Unable to test Click here to open photos and videos of this item.  
Starter Operational; Not operationally checked
Turbo or Blower No visible damage
Injector pump Operational
Exhaust System Unable to test
Radiator
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check The engine started and ran.; Unable to check all components due to position
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational
Steering Brakes
Service Brakes
Drive Motors
Final Drives
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Hydraulic Motors
Valves Grease residue
Hydraulic Tank Low level
Hoses (Hydraulics) Dripping leak; All hoses needs to be replaced,many leaks on
Cylinders Oil seepage
Cylinder Pins and Bushings Moderate to heavy
Limited Function Check The hydraulic system was operational except as noted.
(7)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Main Frame
Stake Down System Operational
Thrust Chain / Sprockets Moderate
Kelly Drive Gear Box
Kelly Slide Wear Plates Moderate
Hyd. Hose Carrier System Manual
Water / Mud Pump
Mud Mixing System
Drill Rod Racks 3 rod racks
Limited Function Check The main components were operational with movement as indicated
(22)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.