Previous Next
Sold on
26/10/17
Winning Bid
US $13,000
Won using Buy Now Price
# of Bids
1
SOLD!
ITEM DETAILS
Mileage
15,618 Hours
VIN
60kW, 3,000 GPH, 240/416 Volts 3 Phase, 120/208 Volts 3 Phase, Diesel Engine, 120V Receptacles, Fuel Tank, Container Enclosure, Tandem Axle Trailer Chassis, Air Brakes

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
DTID Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(15)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Click here to open photos and videos of this item.  
Oil Pressure No oil pressure indicator
Engine Warning Lights Click here to open photos and videos of this item.  
Hour Meter 15,618 Hours - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The item was not operational. Ratings are based on a static inspection.
(4)


Engine
Description Rating Details  
Fuel Type Diesel
Starter Inoperable
Injector pump Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Right Side Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Limited Function Check The engine could not be started.
(10)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator The generator is not producing electricity. Click here to open photos and videos of this item.  
Cables and Connections
Emergency Shut Off Switch Click here to open photos and videos of this item.  
Receptacles Click here to open photos and videos of this item.  
Limited Function Check The unit could not be started and run. Some components could not be properly checked.
(4)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brakes were not operationally checked.
Left Tire Flat Click here to open photos and videos of this item.  
Right Tire Flat Click here to open photos and videos of this item.  
Right Rear Tire Flat Click here to open photos and videos of this item.  
Left Rear Tire Flat Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition Click here to open photos and videos of this item.  
Lights/wiring Condition Not operationally checked
Marker Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Brake Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(13)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.