Home Page / 1999 Caterpillar 14H Motor Grader
 

1999 Caterpillar 14H Motor Grader (#436472)

Search for other Motor Graders items

Winning Bid: €115,000
Won using: Win It Now
 
# of Bids: 1   View Bid History
Sold on: 30/07/13
Auction Type: Daily Marketplace
SOLD!
Features: Enclosed Cab, A/C, Heater, CAT 3306 Engine, 20.5R25 Tires, Push Block, Rear Ripper, 4260 mm Blade
Meter Reading: 16,974 Hours
Serial Number:
Location: Galicia, Spain
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) Yes
Paint Scratches; Chips; some parts have been re-painted, Y frame,and both sides
Sheet Metal (Fiberglass) Condition Minor dents; Surface rust
Steps/Ladders No visible damage
Hand Rails No visible damage
General Appearance - Grader #1
 
Control Station - Grader
Mirrors
Cab Glass See photos for condition; No visible damage; hole on floor mat
Seats/armrests Burn holes; freeplay on frame
Seat belts Operational
Horn Operational
Control Lock Lever
Hydraulic Controls -Grader Loose; Worn
Steering Controls Minimal steering wheel play
Powertrain controls Loose
Oil Pressure full PSI; The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Functional Yes; Some damaged; RR pilot
Engine Warning Lights Operational
Travel Alarm Operational; Weak
Gauges Operational
Hour Meter/Odometer 16,974 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Air Conditioner Operational; Cool but not cold
Heater Operational
Limited Function Check (cs) The main components operated except as noted.
Hour Meter/Odometer (Start)
 
Engine - Grader
Emission Control Label None found
Blow by @ idle (subjective observation) Minor
Starter Operational
Turbo or Blower No visible damage
Injector pump Operational
Exhaust System No visible damage
Radiator
Oil Leaks Seepage: Side of engine; Seepage: Oil Pan; Seepage: Valve cover; fluid accumulation on air compressor,oil seepage on inyector pump regulator and on inyector pump cover, both need to be sealed
Fuel Leaks Seepage: Fuel line; fuel seepage on inyector, oil seepage on pump
Cooling System Leaks None seen
Limited Function Check After jump starting, the engine ran.; except as noted. See oil report.
Blow by @ idle (subjective observation)
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission Type (Motorgrader) 8 FR / 8 RV speeds; Powershift; unable to test all gears due to the location
Transmission Operational; Seepage; grease residue, oil residue on torque also
Rear Axle
Rear Tandems (Chain Drives) Fluid Accumulation
Final Drives
Limited Function Check The drivetrain was operational. See oil report.
Drivetrain #1
 
Hydraulics
Pumps (Hydraulics) Fluid accumulation
Valves Seepage
Hydraulic Tank
Hoses (Hydraulics) Hoses at front of machine: Loose; Hoses in mid section of machine: Loose; Hoses at rear of machine: Loose; Hoses at front of machine: Worn; Hoses in mid section of machine: Worn; Hoses at rear of machine: Worn; Hoses in mid section of machine: Seepage; Hoses in mid section of machine: Braid exposure
Hydraulic Motors Fluid accumulation
Steering Cylinders Heavy pin and bushing movement
Articulation Cylinders Minor to moderate pin and bushing movement
Wheel Lean Cylinders Heavy pin and bushing movement
Blade Lift Cylinders Heavy pin and bushing movement; Welded Pin & Bushing
Blade Angle Cylinders Heavy pin and bushing movement
Blade Side Shift Cylinders Seepage on the right cylinder; Heavy pin and bushing movement; chipped
Saddle Positioning Cylinder Heavy pin and bushing movement
Saddle Lock Pin Operational
Limited Function Check The hydraulic system was operational except as noted.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Blade Tilt Frame (saddle)
Y-frame
Y-frame Pivot Trunnion Heavy movement
Circle Frame and Brackets
Circle Wear Strips Moderate wear
Circle Support Brackets
Circle Gear Box Moderate wear
Circle Gear Worn pinion; moderate wear
Mold Board Slide Wear Strips Moderate wear
Articulating Center Pins Wear Minor to moderate movement
Front Axle Oscillating Pin Wear Heavy movement
Steering Linkage Heavy movement
Wheel Tilt Linkage Visible wear
Belly pans
Limited Function Check (grader) The main chassis components were operational in a limited check.; The main components were operational with movement as indicated.
Brake Type (Motorgrader) Air over hydraulic
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake - Grader
Limited Function Check (Brakes) The brake system functioned, stopping and holding the machine.
Frame Condition
Tire Brands (6) Left Front: michelin; Right Front: michelin; Right Middle: triangle; Right Rear: triangle; Left Rear: triangle; Left Middle: triangle
Tire Condition Cuts; Gouges
Wheel Condition
Wheel Studs, Nuts, Lugs
Chassis #1
 
Specialty
Blade Condition Worn
Blade Cutting Edge Condition (MG) Worn
Ripper Pivot pin wear; heavy wear on all Pin & Bushes
Specialty #1
Oil Sample Analysis Engine Transmission
date of analysis Feb 23, 2013 Feb 23, 2013
Silicon 18 PPM 24 PPM
Lead 1 PPM 10 PPM
Tin 0 PPM 3 PPM
Copper 5 PPM 238 PPM
Aluminum 3 PPM 11 PPM
Silver N/A PPM N/A PPM
Nickel 0 PPM 0 PPM
Chromium 0.6 PPM 0.4 PPM
Iron 37 PPM 105 PPM
Glycol N/A N/A
Water N/A NEG
Fuel N/A N/A

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!