Previous Next
Sold on
06/05/19
Winning Offer
US $30,000
# of Offers
1
SOLD!
ITEM DETAILS
Meter Reading
8,829 Hours
Serial #
Open Operator Station, Dust Collector, Telescoping Boom, Dual Control Stations, Caterpillar 3126 Engine, 12" Track Shoes

**For questions or offers please contact Matt Kennedy 925.233.3622 or Liz Hernandez 925.523.7326 (Se habla español).**

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Functional Operational; Some not operational; Rear work light lights are not operational Click here to open photos and videos of this item.  
(19)


Safety
Description Rating Details  
Travel Alarm Missing
Horn Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Powertrain controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Engine Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 8,828.6 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer 8,829.3 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(13)


Engine
Description Rating Details  
Emission Control Label US EPA certification label Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) Minor; Visible Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks Fuel line Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(15)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Hydrostatic
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Dust collector cylinder rod broken free from collar Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(24)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Belly pans Click here to open photos and videos of this item.  
Boom Condition Slight twist in the top of the boom Click here to open photos and videos of this item.  
Drill Drive Head Operational Click here to open photos and videos of this item.  
Drifter Operational Click here to open photos and videos of this item.  
Clamps/Vices Click here to open photos and videos of this item.  
Dust Collection System Tube from collar to collector missing Click here to open photos and videos of this item.  
Air Compressor Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned when checked without a load.
Chassis #1 Click here to open photos and videos of this item.  
(23)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Overall width (outside to outside of shoes) 94 1/2" Overall width
Track Tensioners Operational
Shoe Width 12" track shoes
Grouser Height Left Side: 29 mm; Right Side: 29 mm
Track link wear Click here to open photos and videos of this item.  
Pins and Bushings Rotated? No Click here to open photos and videos of this item.  
Carrier rollers wear Click here to open photos and videos of this item.  
Track rollers wear Full rock guards; Not visible
Idlers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(14)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Apr 09, 2019 Apr 09, 2019
Silicon 11.16 PPM 6.98 PPM
Tin 0.09 PPM 0 PPM
Silver 0.04 PPM 0.02 PPM
Aluminum 3.39 PPM 2.1 PPM
Chromium 1.8 PPM 0.15 PPM
Lead 0.19 PPM 0 PPM
Copper 0.96 PPM 2.03 PPM
Nickel 0.31 PPM 0.09 PPM
Iron 25.75 PPM 6.12 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.