ITEM DETAILS
Meter Reading
Not Available
Serial #
30kW, 120/208 Volts 3 Phase, 240/416 Volts 3 Phase, Turbo Diesel Engine, Fuel Tank

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
DTID Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition Several panels are missing. Click here to open photos and videos of this item.  
(4)


Control Station - DLA Gen./HVAC Trailer
Description Rating Details  
Gauges The control panel is missing. Click here to open photos and videos of this item.  
Hour Meter (Ending) Not Available - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check (cs) The item was not operational. Ratings are based on a static inspection. The batteries are missing.
(1)


Engine - DLA Gen./HVAC Trailer
Description Rating Details  
Fuel Type Diesel
Injector pump Several fuel system components are missing. Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Right Side Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Limited Function Check The engine is incomplete and could not be started.
(6)


Electrical - DLA Gen./HVAC Trailer
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Receptacles The receptacles are missing.
Limited Function Check (Power Unit) The unit could not be started and run. Some components could not be properly checked.
(2)


DLA - Logistics
Description Rating Details  
Shipping Dimensions - DLA Length: 6'8"; Width: 3'; Height: 4'7"
Machine Weight - DLA Machine weight: 3,000 lbs
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.