ITEM DETAILS
Meter Reading
15,117 Hours
Serial #
550.0 kVA, 440.0 kW, 380 Volts 3 Phase, Volvo TAD1641GE Engine, Electrical Switch Gear, Bottom Mounted Fuel Tank, Skid Mounted, Insulated Enclosure, Container Enclosure, Stationary, CE Plate.

** Screen & Control Panel Have Been Removed & Connected to Totalizing Panel, This Gen Set Is Required To Be Connected To the Totalizing Panel To Operate. 4 x Generators Are Available With Totalizing Unit (See Items 1856876, 1856857 & 1856867).
If Buying Gen Set Seperatley, Seller Must Remove Each Control Panel From Totalizing Unit At There Own Cost **

IMPORTANT NOTICE: This item is in the State of Qatar and is therefore not eligible for export into Bahrain, Egypt, Saudi Arabia or the UAE due to the blockade applied by those countries on the State of Qatar. Bidding from, or shipping to, one of the involved countries on this item is therefore not allowed. Bids from these countries will be canceled. For additional shipping and payment conditions applicable to the purchase of thi

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet metal (fiberglass) condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(26)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Oil Pressure 4.80bar Click here to open photos and videos of this item.  
Engine Warning Lights Operational; One operating warning Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 15117 Hours Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(14)


Engine
Description Rating Details  
Fuel Type Diesel
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Injector pump Not operationally checked; Diesel not used. Seperate diesel tank required. Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran.; A separate electrical panel is required to control start engine and generator Click here to open photos and videos of this item.  
(9)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Disconnect Switch Not operationally checked Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Operational; Operational through panel Click here to open photos and videos of this item.  
Limited Function Check The main components appear to be in place. The generator is producing electricity.; As seen from gauges
(7)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
(1)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.