Previous Next
Sold on
19/09/23
Winning Offer
US $59,500
# of Offers
# of Watchers
23
SOLD!
ITEM DETAILS
Meter Reading
396 Hours
Serial #
Air Conditioner, Hydraulic Cab Riser, Cab Screens, Rear View Camera, 2017 US EPA Label, 8.5 m Boom, 18 ft Stick, Auxiliary Hydraulic Plumbing

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark CE Marked Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Functional Operational Click here to open photos and videos of this item.  
(8)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Operational
Seat belts Operational
Safety lock out/stop Operational Click here to open photos and videos of this item.  
Swing Brake Operational
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes
(2)


Control Station
Description Rating Details  
Seats/armrests Click here to open photos and videos of this item.  
Mirrors Left side broken Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Boom retract function inoperable Click here to open photos and videos of this item.  
Auxiliary Hydraulic Control Untested Click here to open photos and videos of this item.  
Powertrain controls Will not respond to controls, will not run above idle Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure No oil pressure indicator
Engine Warning Lights Check engine light stays on, def fluid, water in fuel, lubrication error light stays on Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 386 hrs Click here to open photos and videos of this item.  
Hour Meter 396 hrs, on replacement meter and the actual hours on the unit are unknown. - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Indication of Additional Hours The following hour meter reading written on the filters is greater than that on the meter: pm sticker showing 12,300 Click here to open photos and videos of this item.  
Cab Air Conditioner The ambient temperature is too cold to check
Cab Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(16)


Engine
Description Rating Details  
Engine 2017 US EPA Label
Emission Label Photo Click here to open photos and videos of this item.  
Air Conditioning Compressor In place; ambient temperature too cold to check operation
Blow-by No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine will not run above idle. Click here to open photos and videos of this item.  
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Left Final Drive Click here to open photos and videos of this item.  
Right Final Drive Click here to open photos and videos of this item.  
Limited Function Check Some components could not be operationally checked., The machine would not move, unit would not run above an idle
(5)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) There is a dripping leak from a hose under the cab Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Capped off, Not operationally checked Click here to open photos and videos of this item.  
Swing Motor Click here to open photos and videos of this item.  
Hydraulic Center Swivel Click here to open photos and videos of this item.  
Boom Lift Cylinder(s) Click here to open photos and videos of this item.  
Stick Cylinder Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational. The hydraulics could only be partially checked for operational, the unit would not run above an idle, stabilizers would not react to controls and the unit has several issues.
(11)


Chassis
Description Rating Details  
Boom Condition Click here to open photos and videos of this item.  
Stick Condition Click here to open photos and videos of this item.  
Boom Base Pin and Bushings Click here to open photos and videos of this item.  
Pin and Bushings Boom to Stick Click here to open photos and videos of this item.  
Turn-table Bearing Click here to open photos and videos of this item.  
Bottom Covers Click here to open photos and videos of this item.  
Limited Function Check The main components were operational in a limited check.
(6)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.